Bachir graduated with a first MEng degree (with honours) in Electrical Engineering and Electronics from the University of Manchester Institute of Science and Technology (UMIST) in 2006. Later, he received his PhD “Image Reconstruction of Low Conductivity Materials using Magnetic Induction Tomography” at the University of Manchester. In 2010, He took up the post of a “Research Associate” at the University of Manchester. Then, he was hired in 2015 by CableDetection Ltd to work as an engineer in the R&D department. Later, in 2017, he joined the BioMediTech Research Institute at the University of Tampere (Finland) where he is currently working as a Senior Research Fellow.

Bachir’s research is in the field of sensing, imaging and signal processing, where he aims to develop innovative ideas and system solutions in the areas of magnetic induction imaging, electrical impedance tomography, non-destructive testing and remote sensing.

In recent years, Bachir’s research has focused on the development of low-cost biomedical systems for detection and continuous monitoring of pathologies including electrical impedance tomography for brain imaging and wireless bioimpedance capsule endoscopy for detection of diseases related to the digestive tract.

Activities

Employment (3)

Tampere University: Tampere, FI

2017-10-01 to present (Faculty of Medicine and Health Technology)
Employment
Source: Self-asserted source
Bachir Dekdouk

CableDetection Ltd: Stoke-on-Trent, GB

2015-01-01 to 2017-09-30
Employment
Source: Self-asserted source
Bachir Dekdouk

University of Manchester: Manchester, GB

2010-04-01 to 2014-12-31 (Department of Electronic and Electrical Engineering)
Employment
Source: Self-asserted source
Bachir Dekdouk

Education and qualifications (1)

University of Manchester: Manchester , GB

Education
Source: Self-asserted source
Bachir Dekdouk

Works (16)

Sensitivity Analysis Highlights the Importance of Accurate Head Models for Electrical Impedance Tomography Monitoring of Intracerebral Hemorrhagic Stroke

IEEE Transactions on Biomedical Engineering
2021 | Journal article
Part of ISSN: 0018-9294
Part of ISSN: 1558-2531
Source: Self-asserted source
Bachir Dekdouk

Absolute imaging of low conductivity material distributions using nonlinear reconstruction methods in magnetic induction tomography

Progress in Electromagnetics Research
2016 | Journal article
EID:

2-s2.0-84954492622

Part of ISSN: 15598985 10704698
Contributors: Dekdouk, B.; Ktistis, C.; Armitage, D.W.; Peyton, A.J.
Source: Self-asserted source
Bachir Dekdouk via Scopus - Elsevier

Contactless inductive bubble detection in a liquid metal flow

Sensors (Switzerland)
2016 | Journal article
EID:

2-s2.0-84953896545

Part of ISSN: 14248220
Contributors: Gundrum, T.; Buttner, P.; Dekdouk, B.; Peyton, A.; Wondrak, T.; Galindo, V.; Eckert, S.
Source: Self-asserted source
Bachir Dekdouk via Scopus - Elsevier

Inductive detection of gas bubbles in a liquid metal flow: A contactless and non invasive methode

2015 IEEE SENSORS - Proceedings
2015 | Conference paper
EID:

2-s2.0-84963614695

Contributors: Gundrum, T.; Buttner, P.; Wondrak, T.; Galindo, V.; Eckert, S.; Dekdouk, B.; Peyton, A.
Source: Self-asserted source
Bachir Dekdouk via Scopus - Elsevier

Towards metal detection and identification for humanitarian demining using magnetic polarizability tensor spectroscopy

Measurement Science and Technology
2015 | Journal article
EID:

2-s2.0-84946046530

Part of ISSN: 13616501 09570233
Contributors: Dekdouk, B.; Ktistis, C.; Marsh, L.A.; Armitage, D.W.; Peyton, A.J.
Source: Self-asserted source
Bachir Dekdouk via Scopus - Elsevier

Estimating magnetic polarizability tensor of buried metallic targets for land mine clearance

Ultra-Wideband, Short-Pulse Electromagnetics 10
2014 | Conference paper
EID:

2-s2.0-84896595307

Contributors: Dekdouk, B.; Marsh, L.A.; Armitage, D.W.; Peyton, A.J.
Source: Self-asserted source
Bachir Dekdouk via Scopus - Elsevier

Electromagnetic method for detection of gas bubbles in two phase liquid metals flows

7th World Congress in Industrial Process Tomography
2013 | Conference paper
EID:

2-s2.0-84910122106

Contributors: Andreew, O.; Gundrum, T.; Wondrak, T.; Eckert, S.; Gerbeth, G.; Dekdouk, B.; Peyton, A.
Source: Self-asserted source
Bachir Dekdouk via Scopus - Elsevier

Evaluating the conductivity distribution in isotropic polycrystalline graphite using spectroscopic eddy current technique for monitoring weight loss in advanced gas cooled reactors

NDT and E International
2012 | Journal article
EID:

2-s2.0-84865421689

Part of ISSN: 09638695
Contributors: Dekdouk, B.; Chapman, R.; Brown, M.; Peyton, A.J.
Source: Self-asserted source
Bachir Dekdouk via Scopus - Elsevier

Non-contact characterisation of conductivity gradient in isotropic polycrystalline graphite using inductance spectroscopy measurements

Insight: Non-Destructive Testing and Condition Monitoring
2011 | Journal article
EID:

2-s2.0-79951859247

Part of ISSN: 13542575 17544904
Contributors: Dekdouk, B.; Ktistis, C.; Armitage, D.W.; Peyton, A.J.; Chapman, R.; Brown, M.
Source: Self-asserted source
Bachir Dekdouk via Scopus - Elsevier

Assessing the feasibility of detecting a hemorrhagic type stroke using a 16 channel magnetic induction system

Journal of Physics: Conference Series
2010 | Conference paper
EID:

2-s2.0-77954672841

Part of ISSN: 17426596 17426588
Contributors: Dekdouk, B.; Ktistis, C.; Armitage, D.W.; Peyton, A.J.
Source: Self-asserted source
Bachir Dekdouk via Scopus - Elsevier

Evaluation of the effects of the screen based on an analytical solution of a simplified MIT system

Journal of Physics: Conference Series
2010 | Conference paper
EID:

2-s2.0-77954682298

Part of ISSN: 17426596 17426588
Contributors: Yin, W.; Dekdouk, B.; Ktistis, C.; Peyton, A.J.
Source: Self-asserted source
Bachir Dekdouk via Scopus - Elsevier

Non-contact characterisation of conductivity gradient in isotropic polycrystalline graphite using inductance spectroscopy measurements

Non-Destructive Testing Conference 2010, NDT 2010
2010 | Conference paper
EID:

2-s2.0-84906262318

Contributors: Dekdouk, B.; Chapman, R.; Brown, M.; Ktistis, C.; Armitage, D.; Peyton, A.J.
Source: Self-asserted source
Bachir Dekdouk via Scopus - Elsevier

The application of a priori structural information based regularization in image reconstruction in magnetic induction tomography

Journal of Physics: Conference Series
2010 | Conference paper
EID:

2-s2.0-77954675970

Part of ISSN: 17426596 17426588
Contributors: Dekdouk, B.; Ktistis, C.; Yin, W.; Armitage, D.W.; Peyton, A.J.
Source: Self-asserted source
Bachir Dekdouk via Scopus - Elsevier

A method to solve the forward problem in magnetic induction tomography based on the weakly coupled field approximation.

IEEE transactions on bio-medical engineering
2009-11-20 | Journal article
Source: Self-asserted source
Bachir Dekdouk
grade
Preferred source (of 2)‎

A feasibility study on the delectability of edema using magnetic induction tomography using an analytical model

IFMBE Proceedings
2008 | Conference paper
EID:

2-s2.0-70350662907

Part of ISSN: 16800737
Contributors: Dekdouk, B.; Pham, M.H.; Armitage, D.W.; Ktistis, C.; Zolgharni, M.; Peyton, A.J.
Source: Self-asserted source
Bachir Dekdouk via Scopus - Elsevier

Developments in magnetic induction tomography for oil-industry applications

5th World Congress in Industrial Process Tomography
2007 | Conference paper
EID:

2-s2.0-84910127361

Contributors: Watson, S.; Ktistis, C.; Dekdouk, B.; Armitage, D.W.; Peyton, A.J.; Williams, R.J.; Griffiths, H.
Source: Self-asserted source
Bachir Dekdouk via Scopus - Elsevier